Hollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter Module

Product Details
Customization: Available
Type: Aw201 Hart Temperature Transmitter Module
Measuring Medium: Liquid, Gas
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 60 foreign trading staff(s) and 38 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (34)
Find Similar Products

Basic Info.

Model NO.
AW201 HART Temperature Transmitter Module
IP Rating
IP20
Customized
Customized
Nominal Voltage
24 VDC
Power Supply
17 to 40 VDC
Alarm Output
≤ 3.8 Ma or ≥ 20.5 Ma
Output Signal
4 to 20mA + Hart
Cold Junction Compensation
Support Built-in / Built-out
Maximum Consumption Current
≤3.15 Ma
Maximum Load Resistance
R = (U Power Supply-12) / 0.024
Galvanic Isolation
500 VAC (Input/Output)
Insolation Resistance
≥ 50 Ω
Response Time
≤ 500 Ms
Start Delay
≤ 6 S
Connection Type
2-Wire, 3-Wire, 4-Wire
Transport Package
Paper Carton and as Buyer&Prime, S Requirement
Specification
6cm × 6cm × 5cm
Trademark
HollySys
Origin
China
HS Code
9025191090
Production Capacity
50, 000+ PCS/Year

Product Description

The temperature transmitter converts the field resistance temperature detector (RTD) or thermocouple (TC) signal into a standard current signal of 4 to 20 mA for control and remote transmission. It supplies secondary instruments such as indication alarms, recorders, regulators, and DCS for measurement, indication, and process regulation.

Features
·  Isolation type temperature transmitter: input/output signal isola tion, meeting 500V electrical isolation (input/output).
·  High-performance precision conversion: stable and reliable, long service life.
·  Internal/external cold junction compensation can be selected, with linear calibration and testing of various signal types.
·  Fast response: the response time is within 500ms.
·  It has strong anti-electromagnetic and radio frequency interference capabilities, and complies with IEC/EN61326 standards.
·  Diagnosic function: self-fault diagnosis, sensor disconnection short circuit diagnosis, variable upper and lower limit detection and other diagnosis.
·  Supports HART5/7 (optional). Through the HART interface, the temperature transmitter module can be configured and maintained for specific applications.
·  Modular glue-filled packaging treatment, moisture-proof, anti-vibration, large temperature range, suitable for a vari ety of complex working conditions.
·  Intrinsic safety explosion-proof and dust explosion-proof: suitable for explosive site installation and use.

Main Parameters
·  Output signal: 4 to 20mA + HART
·  Nominal voltage: 24 VDC
·  Power supply: 17 to 40 VDC
·  Alarm output: ≤ 3.8 mA or ≥ 20.5 mA
·  Cold junction compensation: Support built-in / built-out, accuracy: ≤ 0.5°C
·  Maximum consumption current: ≤3.15 mA
·  Maximum load resistance: R = (U Power Supply-12) / 0.024
·  Protection rating: IP20
·  Galvanic isolation: 500 VAC (Input/Output)
·  Insolation resistance: ≥ 50 Ω
·  Response time: ≤ 500 ms
·  Start delay: ≤ 6 s
·  Connection type: 2-wire, 3-wire, 4-wire

Usage Environment
·  Working temperature: -40°C to +85°C
·  Storage temperature: -40°C to +85°C
·  Relative humidity: 5% to 95%
·  Atmospheric pressure: 86 kPa to 106 kPa

Safety Approval
·  Explosion-proof grade: Ex ia IIC T4/T6 Ga, Ex ia llC T85°C/T135°C Db
·  Explosion-proof certificate: GYB23.2660X
·  Certification standard: GB3836.1, GB3836.

Application
·  Temperature transmitter, divided into HART® communication and USB version, converts different types of input signals into 4 to 20 mA analog output signals.
·  AW201 temperature transmitter with HART® communication features, excellent performance, long-term high stability, and high measurement accuracy, equipped with advanced diagnostic functions.
·  Universal input signal: connect resistance temperature detector (RTD), thermocouple (TC).

Model Code
Model Type Code Description
Type AW 201 - A01 4 to 20 mA + HART
Configuration software +1 Unavailable
+2 AW Tool
Calibration certificate A Unavailable
B 5-point calibration certificate
Transient protect T Integral transient protector
Input (configuration) 1 Configue according to customer requirements
2 Pt100, 3-wire, 0 to 100ºC
Output S 4 to 20 mA, 2-wire
 
Packaging & Delivery
Category Product Size International Commercial Terms (Incoterms) Terms of Payment Nearest Port
AW201 6 cm * 6 cm * 5 cm CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou,Tianjin

Related Products
AW202 Temperature Transmitter Module
Hollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter Module
Hollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter Module

Company Profile
Hollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter Module
Hollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter ModuleHollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter ModuleHollysys Aw201 4~20mA+Hart USB Connection Supported Temperature Transmitter Module

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier