Customization: | Available |
---|---|
Type: | Single Flange Pressure Transmitter |
Structure Type: | Mono-Crystalline Silicon Sensor |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
About AT5020 Single Flange Pressure Transmitter
With internationally leading monocrystalline silicon sensor technology and patented packaging process, AT5020 single flange pressure transmitter is a high-performance pressure transmitter. The monocrystalline silicon sensor is located at the top of the metal body, away from the contact surface of the medium, to achieve mechanical isolation and thermal isolation. The sintered glass integrated sensor leads achieve high-strength electrical insulation with a metal matrix, improving the electronic circuit's flexible performance and ability to withstand transient voltage protection. The monocrystalline silicon sensor packaging technologies ensure that AT5020 single flange pressure transmitter can handle complex chemical and mechanical loads while providing strong electromagnetic interference resistance for demanding industrial environment applications.
Model Type | Code | Description |
AT5020 | DN20/DN25/DN32 single flange pressure transmitter (±0.2% FS accuracy) | |
Type | YTG | Monocrystalline silicon sensor (gauge pressure, -100 kPa to 25 MPa) |
YTA | Monocrystalline silicon sensor (absolute pressure, 0 kPa to 10 MPa) | |
Range | 3 | -40 to 40 kPa (minimum range 0 to 20 kPa for both gauge and absolute pressure) |
4 | -100 to 250 kPa | |
5 | -0.1 to 1 MPa | |
6 | -0.1 to 3 MPa | |
7 | -0.1 to 10 MPa | |
8 | 0 to 25 MPa | |
Electrical connection & housing | E1 | Aluminum housing, polyester coating, 1/2 NPT F, cable entry |
E2 | Aluminum housing, polyester coating, M20 × 1.5 F, cable entry | |
E3 | SS316 housing, 1/2 NPT F, cable entry | |
E4 | SS316 housing, M20 × 1.5 F, cable entry | |
Output signal | R | 24 V DC loop power supply, 4-20 mA, HART 7, two-wire |
Display mode | M5 | LCD with backlight display module, physical buttons |
Process flange | -S6 | SS316 |
-X | More optional materials | |
Connection type | SC | Standard connection, applicable medium temperature -25 to 85ºC |
HC | Heat sink connection, applicable for medium temperature -40 to 150ºC | |
LC | Extra-long heat sink connection, applicable medium temperature -40 to 300°C | |
Isolation fluid | S | Normal temperature silicone oil, temperature range -40 to 205°C |
H | High temperature silicone oil, temperature range 0 to 315°C | |
Isolation diaphragms | A | SS316L |
C | Tantalum (range ≥ 50 kPa) | |
H | Hastelloy C (range ≥ 50 kPa) | |
P | SS316 and PTFE coating (range ≥ 100 kPa, not available with capillary tube) | |
F | SS316 and PFA coating (range ≥ 100 kPa, not available with capillary tube) | |
G | SS316L gold plated (range ≥ 50 kPa) | |
Process connection | H10 | HG/T 20592-2009 DN25 RF, PN10 to PN40 |
H11 | HG/T 20592-2009 DN25 RF, PN63 | |
H12 | HG/T 20592-2009 DN25 RF, PN100 | |
H13 | HG/T 20592-2009 DN25 RF, PN160 | |
H14 | ASME B16.5 1" RF, Class1500 | |
HA0 | HG/T 20592-2009 DN20 RF, PN10 to PN40 (range ≥ 40 kPa) | |
HA1 | HG/T 20592-2009 DN20 RF, PN63 (range ≥ 40 kPa) | |
HA2 | HG/T 20592-2009 DN20 RF, PN100 (range ≥ 40 kPa) | |
HA3 | HG/T 20592-2009 DN20 RF, PN160 (range ≥ 40 kPa) | |
HA4 | ASME B16.5 3/4" RF, Class1500 (range ≥ 40 kPa) | |
HB0 | HG/T 20592-2009 DN32 RF, PN10 to PN40 | |
HB1 | HG/T 20592-2009 DN32 RF, PN63 | |
HB2 | HG/T 20592-2009 DN32 RF, PN100 | |
HB3 | HG/T 20592-2009 DN32 RF, PN160 | |
HB4 | ASME B16.5 1¼" RF, Class1500 | |
X | Optional flange | |
Anti-explosion | d | ExdbIICT6...T4 Gb, NEPSI |
i | ExiaIICT4 Ga, NEPSI | |
NA | Unavailable | |
Special treatment | T | Degreasing (removing oil and grease from product surface) |
NA | Unavailable | |
Mounting bracket | B4 | U and L bracket, 2" tube, carbon steel |
B5 | U and L bracket, 2" pipe, SS304 steel | |
B6 | U and L bracket, 2" pipe, SS316 steel | |
NA | Without bracket (optional when no capillary pipe) | |
Capillary | NA | Capillary-free |
01 | 1 m SS316 capillary pipe, PVC sheath and armored SS304 | |
02 | 2 m SS316 capillary pipe, PVC sheath and armored SS304 | |
03 | 3 m SS316 capillary pipe, PVC sheath and armored SS304 | |
04 | 4 m SS316 capillary pipe, PVC sheath and armored SS304 | |
05 | 5 m SS316 capillary pipe, PVC sheath and armored SS304 | |
Accuracy | 1 | Ultra accuracy ±0.1% (unavailable if range ≤ 20 kPa, unavailable for DN20 flange) |
NA | Standard ±0.2% |
Additional Options | |
Extended warranty | 2-year warranty |
3-year warranty | |
Flushing ring | SS316, clamping type |
Subsidiary requirements | English stainless steel nameplate |
Russian stainless steel nameplate | |
Anti-explosion cable gland, SS316, 1/2 NPT, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Anti-explosion cable gland, SS316, M20 × 1.5, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Nickel plated brass cable gland, 1/2 NPT, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Nickel plated brass cable gland, M20 × 1.5, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Report | Calibration certificate |
Special certifications | SIL |
ATEX Exd | |
ATEX Exia | |
Certificate of Compliance | |
IEC Exd | |
IEC Exia | |
NACE | |
PMI certificate | |
EN10204 | |
Alarm output | NAMUR NE43 analog output, high alarm, 20.8 mA |
NAMUR NE43 analog output, low alarm, 3.8 mA |
Model Type | Code | Description |
AT5020 | DN40/DN50 single flange pressure transmitter (±0.2% FS accuracy) | |
Type | YTG | Monocrystalline silicon sensor (gauge pressure, -100 kPa to 25 MPa) |
YTA | Monocrystalline silicon sensor (absolute pressure, 0 kPa to 10 MPa) | |
Range | 3 | 0 to 40 kPa (gauge pressure: minimum range 0 to 7 kPa; absolute pressure: minimum range 0 to 20 kPa) |
4 | -100 to 250 kPa | |
5 | -0.1 to 1 MPa | |
6 | -0.1 to 3 MPa | |
7 | -0.1 to 10 MPa | |
8 | 0 to 25 MPa | |
Electrical connection & housing | E1 | Aluminum housing, polyester coating, 1/2 NPT F, cable entry |
E2 | Aluminum housing, polyester coating, M20 × 1.5 F, cable entry | |
E3 | SS316 housing, 1/2 NPT F, cable entry | |
E4 | SS316 housing, M20 × 1.5 F, cable entry | |
Output signal | S | 24 V DC loop power supply, 4 to 20 mA, HART 7, two-wire |
Display mode | M5 | LCD with backlight display module, physical buttons |
Process flange | -S6 | SS316 |
Connection type | SC | Standard connection, applicable medium temperature -25 to 85ºC |
HC | Heat sink connection, applicable for medium temperature -40 to 150ºC | |
LC | Extra-long heat sink connection, applicable medium temperature -40 to 200°C | |
Isolation fluid | S | Normal temperature silicone oil, temperature range -40 to 205°C |
H | High temperature silicone oil, temperature range 0 to 315°C | |
Isolation diaphragms | A | SS316L |
C | Tantalum (range ≥ 10 kPa) | |
H | Hastelloy C-276 (range ≥ 10 kPa) | |
P | SS316 and PTFE coating (range ≥ 50 kPa) | |
F | SS316 and PFA coating (range ≥ 50 kPa) | |
G | SS316 gold plated (range ≥ 10 kPa) | |
Process connection | H20 | HG/T 20592-2009 DN50 RF, PN10 to PN40 |
H21 | HG/T 20592-2009 DN50 RF, PN63 | |
H22 | HG/T 20592-2009 DN50 RF, PN100 | |
H23 | HG/T 20592-2009 DN50 RF, PN160 | |
H24 | ASME B16.5 2" RF, Class1500 | |
HC0 | HG/T 20592-2009 DN40 RF, PN10 to PN40 | |
HC1 | HG/T 20592-2009 DN40 RF, PN63 | |
HC2 | HG/T 20592-2009 DN40 RF, PN100 | |
HC3 | HG/T 20592-2009 DN40 RF, PN160 | |
HC4 | ASME B16.5 1½" RF, Class1500 | |
X | Optional flange | |
Anti-explosion | d | ExdbIICT6...T4 Gb, NEPSI |
i | ExiaIICT4 Ga, NEPSI | |
NA | Unavailable | |
Special treatment | T | Degreasing (removing oil and grease from product surface) |
NA | Unavailable | |
Mounting bracket | B4 | U and L bracket, 2" pipe, carbon steel |
B5 | U and L bracket, 2" pipe, SS304 steel | |
B6 | U and L bracket, 2" pipe, SS316 steel | |
NA | Without bracket (optional when no capillary tube) | |
Capillary | NA | Capillary-free |
01 | 1 m capillary tube, PVC sheath and armored SS304 | |
02 | 2 m capillary tube, PVC sheath and armored SS304 | |
03 | 3 m capillary tube, PVC sheath and armored SS304 | |
04 | 4 m capillary tube, PVC sheath and armored SS304 | |
05 | 5 m capillary tube, PVC sheath and armored SS304 | |
06 | 6 m capillary tube, PVC sheath and armored SS304 | |
07 | 7 m capillary tube, PVC sheath and armored SS304 | |
08 | 8 m capillary tube, PVC sheath and armored SS304 | |
09 | 9 m capillary tube, PVC sheath and armored SS304 | |
10 | 10 m capillary tube, PVC sheath and armored SS304 | |
Accuracy | 1 | Ultra accuracy ±0.1% (unavailable if range ≤ 10 kPa, unavailable if capillary length ≥ 6 m) |
NA | Standard ±0.2% |
Additional Options | |
Extended warranty | 2-year warranty |
3-year warranty | |
Flushing ring | SS316, clamping type |
Subsidiary requirements | English stainless steel nameplate |
Russian stainless steel nameplate | |
Anti-explosion cable gland, SS316, 1/2 NPT, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Anti-explosion cable gland, SS316, M20 × 1.5, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Nickel plated brass cable gland, 1/2 NPT, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Nickel plated brass cable gland, M20 × 1.5, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Report | Calibration certificate |
Special certifications | SIL |
ATEX Exd | |
ATEX Exia | |
Certificate of Compliance | |
IEC Exd | |
IEC Exia | |
NACE | |
PMI certificate | |
EN10204 | |
Alarm output | NAMUR NE43 analog output, high alarm, 20.8 mA |
NAMUR NE43 analog output, low alarm, 3.8 mA |
Model Type | Code | Description |
AT5020- | DN65/DN80 single flange pressure transmitter (±0.2% FS accuracy) | |
Type | YTG | Monocrystalline silicon sensor (gauge pressure, -100 kPa to 10 MPa) |
YTA | Monocrystalline silicon sensor (absolute pressure, 0 kPa to 10 MPa) | |
Range | 3 | -40 to 40 kPa (gauge pressure: minimum range 0 to 7 kPa; absolute pressure: minimum range 0 to 20 kPa) |
4 | -100 to 250 kPa | |
5 | -0.1 to 1 MPa | |
6 | -0.1 to 3 MPa | |
7 | -0.1 to 10 MPa | |
Electrical connection & housing | E1 | Aluminum housing, polyester coating, 1/2 NPT F, cable entry |
E2 | Aluminum housing, polyester coating, M20 × 1.5 F, cable entry | |
E3 | SS316 housing, 1/2 NPT F, cable entry | |
E4 | SS316 housing, M20 × 1.5 F, cable entry | |
Output signal | S | 24 V DC loop power supply, 4 to 20 mA, HART 7, two-wire |
Display mode | M5 | LCD with backlight display module, physical buttons |
Process flange | -S6 | SS316 |
Connection type | SC | Standard connection, applicable medium temperature -25 to 85ºC |
HC | Heat sink connection, applicable for medium temperature -40 to 150ºC | |
LC | Extra-long heat sink connection, applicable medium temperature -40 to 200°C | |
Isolation fluid | S | Normal temperature silicone oil, temperature range -40 to 205°C |
H | High temperature silicone oil, temperature range 0 to 315°C | |
Isolation diaphragms | A | SS316L |
C | Tantalum (range ≥ 10 kPa) | |
H | Hastelloy C-276 (range ≥ 10 kPa) | |
P | SS316 and PTFE coating (range ≥ 50 kPa) | |
F | SS316 and PFA coating (range ≥ 50 kPa) | |
G | SS316L gold plated (range ≥ 10 kPa) | |
Process connection | H30 | HG/T 20592-2009 DN80 RF, PN10 to PN16 |
H31 | HG/T 20592-2009 DN80 RF, PN25 to PN40 | |
H32 | HG/T 20592-2009 DN80 RF, PN63 | |
H33 | HG/T 20592-2009 DN80 RF, PN100 | |
H34 | HG/T 20592-2009 DN80 RF, PN160 | |
HD0 | HG/T 20592-2009 DN65 RF, PN10 to PN16 | |
HD1 | HG/T 20592-2009 DN65 RF, PN25 to PN40 | |
HD2 | HG/T 20592-2009 DN65 RF, PN63 | |
HD3 | HG/T 20592-2009 DN65 RF, PN100 | |
HD4 | HG/T 20592-2009 DN65 RF, PN160 | |
X | Optional flange | |
Anti-explosion | d | ExdbIICT6...T4 Gb, NEPSI |
i | ExiaIICT4 Ga, NEPSI | |
NA | Unavailable | |
Special treatment | T | Degreasing (removing oil and grease from product surface) |
NA | Unavailable | |
Mounting bracket | B4 | U and L bracket, 2" pipe, carbon steel |
B5 | U and L bracket, 2" pipe, SS304 steel | |
B6 | U and L bracket, 2" pipe, SS316 steel | |
NA | Without bracket (optional when no capillary tube) | |
Capillary | NA | Capillary-free |
01 | 1 m SS316 capillary tube, PVC sheath and armored SS304 | |
02 | 2 m SS316 capillary tube, PVC sheath and armored SS304 | |
03 | 3 m SS316 capillary tube, PVC sheath and armored SS304 | |
04 | 4 m SS316 capillary tube, PVC sheath and armored SS304 | |
05 | 5 m SS316 capillary tube, PVC sheath and armored SS304 | |
06 | 6 m SS316 capillary tube, PVC sheath and armored SS304 | |
07 | 7 m SS316 capillary tube, PVC sheath and armored SS304 | |
08 | 8 m SS316 capillary tube, PVC sheath and armored SS304 | |
09 | 9 m SS316 capillary tube, PVC sheath and armored SS304 | |
10 | 10 m SS316 capillary tube, PVC sheath and armored SS304 | |
Accuracy | 1 | Ultra accuracy ±0.1% (unavailable if range ≤ 10 kPa, unavailable if capillary length ≥ 6 m) |
NA | Standard ±0.2% |
Additional Options | |
Extended warranty | 2-year warranty |
3-year warranty | |
Flushing ring | SS316, clamping type |
Subsidiary requirements | English stainless steel nameplate |
Russian stainless steel nameplate | |
Anti-explosion cable gland, SS316, 1/2 NPT, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Anti-explosion cable gland, SS316, M20 × 1.5, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Nickel plated brass cable gland, 1/2 NPT, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Nickel plated brass cable gland, M20 × 1.5, cable diameter 6 to 8 mm, optional 11 to 17 mm | |
Report | Calibration certificate |
Special certifications | SIL |
ATEX Exd | |
ATEX Exia | |
Certificate of Compliance | |
IEC Exd | |
IEC Exia | |
NACE | |
PMI certificate | |
EN10204 | |
Alarm output | NAMUR NE43 analog output, high alarm, 20.8 mA |
NAMUR NE43 analog output, low alarm, 3.8 mA |
Category | Product Size | International Commercial Terms (Incoterms) | Terms of Payment | Nearest Port |
AT5020 DN20/DN25/DN32 Single Flange Pressure Transmitter | 18 cm*18 cm*25 cm | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |
AT5020 DN40/DN50 Single Flange Pressure Transmitter | 18 cm*18 cm*25 cm | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |
AT5020 DN65/DN80 Single Flange Pressure Transmitter | 18 cm*18 cm*25 cm | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |