Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis

Product Details
Customization: Available
Task: Program
Signal: Continuous
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 60 foreign trading staff(s) and 38 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (34)
  • Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
  • Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Find Similar Products

Basic Info.

Model NO.
HiaGuard SIL3 SIS
Function
Automatic Control, Protection, Monitoring
Certification
Sil3
Condition
New
Customized
Customized
Degraded Mode
3-2-0
Power Supply
1+1 Redundant Power Supply
System Availability
99.999%
Modular Design
Triple-Modular
Transport Package
Transported in Standard Packaging
Trademark
HollySys
Origin
China
HS Code
8537101101
Production Capacity
8, 000 Sets/Year

Product Description

HiaGuard SIL3 SIS is developed by HollySys and specifically designed for the industrial automation safety sector. It has been certified by TÜV Rheinland in Germany. The system adheres to IEC 61508 and IEC 61511 standards, achieving SC3 system capability and SIL3 safety integrity levels, making it suitable for safety-related applications. Since its launch, HiaGuard SIS has been implemented in thousands of functional safety scenarios across various industries worldwide, including refining and petrochemicals, coal chemicals, oil and gas production, storage and transportation, energy and power generation, metallurgy, papermaking, food and pharmaceutical, among others. The system is committed to leveraging cutting-edge technology to enhance the safety and reliability of production units while providing customers with excellent safety assurance and operational efficiency.

Product Features
High Availability
HiaGuard SIL3 SIS adopts 2oo3D (2-out-of-3 with Diagnostics) technology, ensuring outstanding advantages in safety, stability, and real-time performance. Additionally, the system supports a 3-2-0 degradation mode, ensuring continued availability under abnormal conditions, with availability reaching up to 99.999%.

Safety Compliance
HiaGuard SIL3 SIS meets international safety standards IEC 61508 and IEC 61511 SC3 system capability level and SIL3 safety integrity level. It has received certification from TÜV Rheinland in Germany, as well as CE Certification (including EMC and LVD), G3 Anticorrosion Certification, CCS, and Achilles Certification.

Accurate Diagnostics
HiaGuard SIL3 SIS offers comprehensive diagnostic capabilities with a diagnostic coverage of over 90%, allowing precise fault localization down to the channel level. Its 1-ms resolution Sequence of Events (SOE) recording accurately captures operational details. The application of the HART protocol facilitates easier calibration and maintenance of field instruments.

Integrated Safety
HiaGuard SIL3 SIS can be seamlessly integrated with HollySys DCS through a unified system network, sharing physical network resources but maintaining logical separation with different protocols. A failure on the DCS side does not impact SIS safety. Operators can access real-time data from both DCS and SIS via human-machine interface, simplifying data acquisition and management processes and reducing software and hardware costs.

Protocols and Interfaces
HiaGuard SIL3 SIS is compatible with Profibus, TCP/IP, and Modbus communication protocols. It uses RS485 and Ethernet interfaces to enable one-way or two-way data exchange with other systems via communication stations or switches.

Secure Communication
Communication between HiaGuard system stations adopts a safety communication protocol that complies with functional safety standards. It employs black channel technology to forward and transmit safety data via communication modules and switches, ensuring data security.

System Architecture
HiaGuard SIL3 SIS mainly consists of engineering stations, operator stations, historian stations, and control stations, forming the system network and control network. The control network's nodes consist of control stations and I/O modules. HiaGuard SIS supports up to 15 domains, each supporting 64 control stations, with each single station supporting a maximum of 1,856 I/O points. The main rack supports up to 224 I/O points.
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Product Images
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Packaging & Delivery
Category International Commercial Terms (Incoterms) Terms of Payment Nearest Port
HiaGuard SIL3 SIS CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou, Tianjin

Related Products
LKS SIL2 SIS
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis

Company Profile
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System SisHollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System SisHollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System SisHollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier