Technical Parameters
· Input Current Range: The range of current that can be measured by the current transducer.
· Maximum Input Current: The upper limit of current that the transducer can accept without damaging its performance. Exceeding this value may cause permanent damage to the transducer.
· Input Voltage Range: The range of voltage that can be measured by the voltage transducer.
· Maximum Input Voltage: The upper limit of voltage that the transducer can accept without damaging its performance. Exceeding this value may cause permanent damage to the transducer.
· Frequency Range: The range of input signal (current or voltage) frequencies that the transducer can accurately measure. Beyond this range, the measurement accuracy of the transducer will decrease.
· Current Output: The transducer represents the input signal magnitude as a 4~20mA or 0~20mA current output.
· Maximum Output Current: When the transducer is set to current output, this is the maximum possible output current if the input signal exceeds the measurement range.
· Current Output Load: When the transducer is set to current output, this is the maximum load resistance it can drive while maintaining output signal accuracy within the current output range.
· Voltage Output: The transducer can be configured to represent the input signal magnitude as a 0~5V or 0~10V voltage output.
· Maximum Output Voltage: When the transducer is set to voltage output, this is the maximum possible output voltage if the input signal exceeds the measurement range.
· Voltage Output Load: When the transducer is set to voltage output, this is the minimum allowable external impedance to ensure output signal accuracy within the voltage output range.
Product Catalogue
Product Code |
Product Name |
Input Signal |
Output Signal |
Power Supply |
AD10IA-10 |
Ac current transmitter |
0 to 1/5/10 A AC |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
20 to 30 V DC |
AD10IA-10A |
Ac current transmitter |
0 to 1/5/10 A AC |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
90 to 260 V AC/120 to 300 V DC |
AD10ID-10 |
Dc current transmitter |
0 to 1/2/5/10 A DC |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
20 to 30 V DC |
AD10ID-10A |
Dc current transmitter |
0 to 1/2/5/10 A DC |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
90 to 260 V AC/120 to 300 V DC |
AD10VA-370 |
Ac voltage transmitter |
0 to 30/50/120/250/500 V AC |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
20 to 30 V DC |
AD10VA-370A |
Ac voltage transmitter |
0 to 30/50/120/250/500 V AC |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
90 to 260 V AC/120 to 300 V DC |
AD10VD-400 |
DC Voltage transmitter |
0 to 100 V/0 to 1,000 V |
0 to 20 mA/4 to 20 mA/1 to 5 V/0 to 5 V/0 to 10 V |
20 to 30 V DC |
Product Features
· Compact housing design
· 35mm standard DIN rail mounting
· Multiple current/voltage output options available
Dimensions
Wire cross section: 0.5 to 2.5 mm2
Packaging & Delivery
Category |
International Commercial Terms (Incoterms) |
Terms of Payment |
Nearest Port |
AD10 Small Power Transmitter |
CIF, CFR, DAP |
LC, T/T, D/P |
Shanghai, Guangzhou, Tianjin |