HollySys AM2000EX isolated safety barriers is used to connect intrinsically safe equipment in hazardous areas. It consists of plug-in modules and a backplane, with each module containing either 1 analog or 2 digital isolated channels. Each module has 2 connectors for plugging into the backplane-one for the intrinsically safe circuit and the other for the non-intrinsically safe circuit. The backplane is housed in a plastic enclosure, which can be mounted on a DIN rail. The backplane provides power and hazardous area wiring terminals, as well as connectors for the non-hazardous area. Each backplane can accommodate up to 8 plug-in AM2000EX modules.
Product Features
Power Supply
· Independent power supply
Number of Channels
· 1-in 1-out, 2-in 2-out
Functions
· Signal isolation, transmission, conversion, and distribution
Compatible Signals and Intrinsically Safe Instruments
· Switch/proximity switch input
· 2-wire/3-wire transmitter input (including HART)
· Current signal input/output
· Thermocouple, millivolt signal, and RTD (resistance temperature detector) input
Product Standards
· GB/T 3836.1-2021 "Explosive Environments Part 1: General Requirements for Equipment"
· GB/T 3836.4-2021 "Explosive Environments Part 4: Intrinsically Safe 'i' Protected Equipment"
· GB/T 3836.20-2010 "Explosive Environments Part 20: Equipment Protection Rank (EPL) Ga-level Equipment "
· GB/T 19001-2008 is equivalent to ISO9001: 2008 "Quality Management System Requirements:"
Product Certifications
· National Instrument Explosion-proof Safety Supervision and Inspection Station Explosion-proof Certification
· AM2000EX Series isolation Grid
· AM2000EX Series Base Plate
· Explosion-proof certificate number: GYB22.2846X
· China Compulsory Product Certification (CCC)
Technical Parameters
Power Protection
· Reverse polarity protection
Safety Isolation
· Isolation between safe side and hazardous side, 250V AC safety voltage
Dielectric Strength
· 2,500 V AC, 1 min (between intrinsically safe and non-intrinsically safe terminals)
Electromagnetic Compatibility (EMC)
· Complies with GB/T 18268 Electromagnetic Compatibility Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use (equivalent to IEC 61326-1)
· Electrostatic Discharge (ESD): 8 kV (air discharge)
· Electrical Fast Transient (EFT): 2 kV (power line to ground), 1 kV (signal line to ground)
· Surge Immunity: 2 kV (line to ground), 1 kV (line to line)
· RF Immunity: 10 V/m
Operating Environment
· Must be installed in a safe area free of explosive gases.
· Avoid strong vibration, shock, and corrosive gases or dust.
· Operating Temperature: -20°C to +60°C (continuous)
· Relative Humidity: 10% to 90% (non-condensing)
Storage Conditions
· Temperature: -40°C to +80°C
· Relative Humidity: 10% to 90% (non-condensing)
Structure and Dimensions
· Housing Structure: AM2000 plastic enclosure
· Installation Method: Installed in safe areas using backplane mounting
· Dimensions: 110.0 mm × 73.0 mm × 12.5 mm (Depth × Height × Width)
Packaging & Delivery
Category |
International Commercial Terms (Incoterms) |
Terms of Payment |
Nearest Port |
AM2000EX Isolated Safety Barrier |
CIF, CFR, DAP |
LC, T/T, D/P |
Shanghai, Guangzhou, Tianjin |
Related Products
AM5000EX Isolated Safety Barrier
AM3000EX Isolated Safety Barrier
AMG1000 Isolator

AML1000 Surge Protective Device (SPD)
Company Profile