Hollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)

After-sales Service: as Required
Warranty: as Required
Accuracy: 1.0%, 1.5%, 2.5%
Usage: Industrial
Display: Digital
Material: Gas, Liquid
Samples:
US$ 199/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 60 foreign trading staff(s) and 38 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (34)

Basic Info.

Model NO.
Remote Thermometer WSSF (R/Z) (N)
Hygrometer Type
Bimetal Thermometer
Nominal Diameters
Φ63, 80, 100, 127, 150
Measurement Range
-80 to 600 ºC
Temperature Variable Voltage
12 to 36VDC
Process Connection
Threaded/Flanged Connection
Guard Material
304ss, 316L
Transport Package
Standard Packing
Trademark
HollySys
Origin
China
HS Code
9025199090
Production Capacity
5, 000 PCS/Year

Product Description

WSSF bimetallic thermometer series is a kind of temperature measurement instrument suitable for direct measurement of vapor and liquid temperature. The imported bimetallic sheet is used as the temperature measuring element, which has high speed and high precision. 304SS stainless steel plasma welding shell, spinning sealing process, has strong shock resistance, splash resistance and corrosion resistance, and is easy to read, durable. It is widely used in petroleum, chemical industry, machinery, shipbuilding, power generation, textile, printing and dyeing, medicine and other industrial and scientific research departments.

Application
The integrated thermometer integrates thermocouple (resistance) and bimetallic temperature measurement elements inside the same temperature measurement probe, and realizes two functions of field indication and signal output. The bimetallic thermometer can be made into a shock-resistant type. The products are widely used in petroleum, chemical industry, machinery, shipbuilding, electric power, textile, printing and dyeing and other industrial and scientific research departments.

Technical Parameters
·  Nominal diameters: Φ63, Φ80, Φ100, Φ127Φ, Φ150
·  Indication accuracy: 1.0%, 1.5%, 2.5%
·  Output accuracy: thermal resistance A, B
                               thermocouples l, ll, lll
·  Temperature variable voltage: 12 to 36VDC
·  Temperature change signal: 4 to 20mA, 1 to 5V (optional)
·  Temperature change accuracy: 0.2 level, 0.5 level
·  Measurement range: -80 to 600 ºC
·  Process connection: threaded connection (movable external thread, movable internal thread, fixed thread, clamping thread)
                                     flanged (movable flange, fixed flange, sanitary flange)

·  Temperature sensing element: bimetallic thermocouple (resistance)
·  Guard Material: 304SS, 316L (customizable as per user)
·  Guard Diameter: Φ10, Φ12, Φ14, Φ16 (other)
·  Case Material: 304SS, 316L
·  Instrument pointer: Aluminum alloy (black)
·  Instrument dial: aluminum alloy (black on white background)
·  Instrument glass: polycarbonate, flat glass, safety glass
·  Protection level: IP65


Options
·  Dial scale: single scale, double scale, color segment indication
·  Gauge head: all steel, electric contact
·  Instrument filling fluid: glycerin, silicone oil, fluorine oil, instrument special oil
·  Output form: resistance, voltage, current
·  Sheath connection: threaded connection (movable external thread, movable internal thread, fixed thread, clamping thread)
                                   flanged (movable flange, fixed flange, sanitary flange)

·  Sheath material: material selected according to medium and temperature
·  Shims material: copper, tetrafluorine (PTFE)


Wiring Diagram
Single ThermocoupleHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)
Single Thermal ResistorHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)
TransmitterHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)

Dimensions
Type Nominal diameter D1 H d I M (F)
Axial direction Φ63 68 33~53 Φ10
Φ12
Φ14

Φ16
50-  to 2000




M20 × 1.5 M27 × 2 G1/2 "1/2" NPT;
F (flange standard)
Φ76 76 36~56
Φ100 101 36~56
Φ127 128 37~57
Φ150 150 38~58
Radial direction Φ63 68 83~103
Φ80 wild card 83 98~118
Φ100 Wild card 100 115~135
Neckar 101 116~136
Φ127 Necal Card 128 143~163
Φ150 Necal Card 150 165~185
Universal direction Φ63 68 103~123
Φ76 76 106~126
Φ100 101 106~126
Φ127 128 107~127
Φ150 150 108~128
Integrated Radial ThermometerHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)
Integral Axial ThermometerHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)
Integrated Universal ThermometerHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)

Selection Table
WSSF (R/Z) Remote thermometer

Integrated form RN
Thermocouple R Thermal resistance Z
P: Pt100
N: K type nickel chromium-nickel silicon  
E: Type E nickel chromium-copper nickel  
F: J type iron-copper-nickel  
C: T-type copper-copper-nickel  
N (oil-filled) N: shock-resistant type
None: Ordinary
Nominal diameter
4
3: Φ76 (80)
4: Φ100
5: Φ127
6: Φ150
8: Φ63
Mounting structure 8 0: Axial
1: Radial
8: Universal


Installation form 16
Installation method Diameter
1: Movable External Thread 6: Φ6.35
2: Movable Internal Thread 8: Φ8
3: Fixed Thread 10: Φ10
4: Movable Flange 12: Φ12
5: Card Sleeve Threads T0: Others
6: Hygienic Chuck  

Install Spec M4
M: metric thread G: Straight pipe thread N: taper thread F: flange/sanitary chuck
1: M14 × 1.5 1: G1/4 " 1: 1/4 "NPT For flanges, see Table 1 for hygienic chucks
1.5",2"
2: M16 × 1.5 2: G3/8 " 2: 3/8 "NPT
3: M20 × 1.5 3: G1/2 " 3: 1/2 "NPT
4: M 27 × 2 4: G3/4 " 4: 3/4 "NPT
5: M33 × 2 5: G1 " 5: 1 "NPT
M1, G1, N1 threads can only be installed with fixed threads
Range W (0 ~ 100) Temperature range:-80 ~ 600 ºC
Insertion length L = 150 Insertion depth L L = 50 ~ 2000mm
Thread length not included

Packaging & Delivery
Category International Commercial Terms (Incoterms) Terms of Payment Nearest Port
Remote Thermometer WSSF (R/Z) (N) CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou, Tianjin

Company ProfileHollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)Hollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)Hollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)Hollysys Industrial Temperature Meter Sensor Remote Thermometer Wssf (R/Z) (N)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now