AM5000EX Isolated Safety Barriers facilitate signal transmission, conversion, monitoring, and control between hazardous and safe areas, featuring high-precision conversion, isolation, and transmission characteristics that more accurately replicate on-site signals. The product's internal design eschews mechanical potentiometers, reducing vibration and long-term operational drift, and its surface is treated with anti-corrosion measures, ensuring stable and reliable long-term operation. Additionally, it boasts an ultra fast response, enabling the monitoring or control of field equipment with minimal delay.
Features
· InIntelligent Diagnosis & Easy Configuration - Streamlined setup with clear zoning for efficient operation.
· Wide Operating Range - Minimal temperature drift (≤0.005% F.S./°C) across -30 to 70°C.
· Easy Installation - Redesigned modular structure accelerates deployment and maintenance.
· Anti-Interference Design - Advanced signal algorithms suppress electromagnetic interference for unwavering performance.
Selection List
Product Name |
Product Model |
Siginal Type |
Number of Channels |
Hazardous Side |
Safe Side |
Additional Functions |
Digital input isolated safety barrier |
AM5011EX |
DI |
1-input 1-output |
Switch, proximity switch input |
Relay output |
Equipped with circuit fault detection function |
AM5011EX.T |
DI |
1-input 1-output |
Transistor output |
AM5012EX |
DI |
1-input 2-output |
Relay output |
AM5013EX |
DI |
2-input 2-output |
Relay output |
Digital output isolated safety barrier |
AM5021EX |
DO |
1-input 1-output |
Output voltage is 212 V when the drive current is 45 mA |
Dry contact input |
/ |
AM5021EX.T |
DO |
1-input 1-output |
|
Wet contact input |
/ |
Analog input isolated safety barrier |
AM5031EX |
Al |
1-input 1-output |
2, 3-wire transmitter input |
0/4 to 20 mA |
/ |
AM5032EX |
Al |
1-input 2-output |
Current source input |
(HART) output |
/ |
Analog output isolated safety barrier |
AM5041EX |
AO |
1-input 1-output |
0/4 to 20 mA (HART) output |
0/4 to 20 mA input |
/ |
AM5041EX.D |
AO |
1-input 1-output |
4 to 20mA (HART) output |
4 to 20 mA input |
With loop detection |
Thermocouple input isolated safety barrier |
AM5051EX |
TC |
1-input 1-output |
Thermocouple, mV input |
|
USB Type-C programming interface |
RTD input isolated safety barrier |
AM5061EX |
RTD |
1-input 1-output |
Thermal resistance input |
0/4 to 20mA output |
Supporting NFC configuration |
TC/RTD input isolated safety barrier |
AM5071EX |
TC/RTD |
1-input 1-output |
Thermocouple, thermal resistance, mV input |
|
|
Technical Data
Product Name |
Product Model |
Siginal Type |
Number of Channels |
Hazardous Side |
Safe Side |
Additional Functions |
Digital input isolated safety barrier |
AM5011EX |
DI |
1-input 1-output |
Switch, proximity switch input |
Relay output |
Equipped with circuit fault detection function |
AM5011EX.T |
DI |
1-input 1-output |
Transistor output |
AM5012EX |
DI |
1-input 2-output |
Relay output |
AM5013EX |
DI |
2-input 2-output |
Relay output |
Digital output isolated safety barrier |
AM5021EX |
DO |
1-input 1-output |
Output voltage is 212 V when the drive current is 45 mA |
Dry contact input |
/ |
AM5021EX.T |
DO |
1-input 1-output |
|
Wet contact input |
/ |
Analog input isolated safety barrier |
AM5031EX |
Al |
1-input 1-output |
2, 3-wire transmitter input |
0/4 to 20 mA |
/ |
AM5032EX |
Al |
1-input 2-output |
Current source input |
(HART) output |
/ |
Analog output isolated safety barrier |
AM5041EX |
AO |
1-input 1-output |
0/4 to 20 mA (HART) output |
0/4 to 20 mA input |
/ |
AM5041EX.D |
AO |
1-input 1-output |
4 to 20mA (HART) output |
4 to 20 mA input |
With loop detection |
Thermocouple input isolated safety barrier |
AM5051EX |
TC |
1-input 1-output |
Thermocouple, mV input |
|
USB Type-C programming interface |
RTD input isolated safety barrier |
AM5061EX |
RTD |
1-input 1-output |
Thermal resistance input |
0/4 to 20mA output |
Supporting NFC configuration |
TC/RTD input isolated safety barrier |
AM5071EX |
TC/RTD |
1-input 1-output |
Thermocouple, thermal resistance, mV input |
|
|
Excellent Quality Management
AM5000EX Isolated Safety Barrier features a comprehensive quality management system, including strict material selection and multi-stage testing, ensuring compliance with international standards. The manufacturing process uses advanced automation and lean control methods, with thorough oversight from assembly to final inspection. This approach ensures the AM5000EX exceeds performance expectations in extreme environments, offering precision and durability for mission-critical applications where reliability is essential.
Packaging & Delivery
Category |
International Commercial Terms (Incoterms) |
Terms of Payment |
Nearest Port |
AM5000EX Isolated Safety Barriers |
CIF, CFR, DAP |
LC, T/T, D/P |
Shanghai, Guangzhou, Tianjin |
Related Products
AM2000EX Isolated Barrier

AM3000EX Isolated Barrier
AMG1000 Isolator

AML1000 Surge Protective Device (SPD)
Company Profile