G80 is the latest product of the 5100 series, which is different from other radar level transmitters in the 5100 series. The G80 frequency can reach 80 GHz. The instrument emits a continuous radar signal through its lens antenna. The frequency of this signal will change like a sawtooth. The transmitted signal is reflected by the medium and received by the antenna as an echo signal. There is always a frequency difference between the received signal frequency and the current transmission frequency. The frequency difference is directly proportional to the material level in the container, and the accurate value of the level is calculated through a specific algorithm of the sensor. The G80 series operates with very low transmission power in the W-band range.
Main Parameters
· Antenna: Lens antenna
· Dielectric Constant: > 1.4
· Measurement Range: 0 to 120 m
· Process Connection: Thread/Flange
· Process Temperature: -40 to 1200ºC
· Process Pressure: -0.1 to 4.0 MPa
· Accuracy: ±1 mm
· Output Signal: 4 to 20 mA, HART 7; Modbus RTU
· Display: LCD display
· Explosion-proof/Protection grade: Ex ia IIC T6 Ga/IP 67
· It has the ability to measure foam of certain thickness, and the thickness of foam is not more than 5 cm.
· Frequency: 80 GHz
Application
· Occasions with high measurement accuracy requirements.
· Improved measurement performance for complex systems with stirring inside the tank.
· Suitable for media with a low dielectric constant.
Model Code
Model Type |
Code |
Description |
Brand |
DHE |
A brand of DHE |
Type |
RD |
Radar level transmitter |
Series |
5100 |
Non-contact radar level transmitter |
Antenna type |
8 |
80 GHz |
Safety certification |
S |
SIL2 |
N |
None |
Explosion-proof certification |
E |
Ex d ia IIC T6 Gb Ex tD A21 IP67 T80ºC |
I |
Ex ia IIC T6 Ga Ex iaD 20 T80ºC IP67 |
N |
Non explosion-proof |
Sensor type |
T |
Lens antenna |
F |
Anti-corrosion antenna |
C |
Purge antenna |
Y |
Special customization |
Range |
010 |
10 m |
020 |
20 m |
030 |
30 m |
060 |
60 m |
120 |
120 m |
Process temperature |
L |
-40 to 85ºC |
M |
-40 to 150ºC |
H |
-40 to 200ºC |
D |
Customized (below -40ºC or above 200ºC) |
Accuracy |
1 |
±1 mm |
3 |
±3 mm |
5 |
±5 mm |
Process connection |
D |
G1 1/2, stainless steel 316L |
J |
G3 1/2, stainless steel 316L |
F |
Flange connection (larger than DN50) |
Y |
Special customization |
Output method |
I |
4 to 20 mA |
H |
4 to 20 mA, HART 7 |
M |
Modbus RTU communication protocol available |
X |
Special customization |
Power supply |
D |
DC 24 V |
A |
AC 220 V |
Lightning protection |
I |
Built-in |
E |
External |
N |
None |
Wire system |
T |
Two-wire system |
F |
Four-wire system |
Display |
X |
None |
L |
LCD |
F |
LCD and split transmitter outfit display |
Housing material |
A |
Cast aluminum alloy |
S |
Stainless steel |
Housing type |
S |
Single-compartment housing |
D |
Dual-compartment housing |
Electrical interface |
M |
M20 × 1.5 |
G |
G 1/2" |
N |
NPT 1/2" |
Y |
Special customization |
Product Images
Drawings

Models and Specifications
Type |
RD |
Radar level gauge |
Series |
5100 |
Non-contact radar level gauge |
Antenna type |
8 |
80GHz |
Safety certification |
S |
SIL2 |
N |
None |
Explosion-proof certification |
E |
Ex dia II CT6 Gb Ex tD A21 IP67 T80ºC |
I |
Ex ia II CT6 Ga Ex iaD 20 T80ºC IP67 |
N |
Non explosion-proof |
Sensor type |
T |
Lens antenna |
F |
Anti-corrosion antenna |
C |
Purge antenna |
Y |
Special customization |
Range |
010 |
10m |
020 |
20m |
030 |
30m |
060 |
60m |
120 |
120m |
Process temperature |
L |
(-40~85)ºC |
M |
( -40~ 150)ºC |
H |
(-40~200)ºC |
D |
Customized (below -40 ºC or above 200 ºC) |
Accuracy |
1 |
± 1mm |
3 |
±3mm |
5 |
±5mm |
Process connection |
D |
G11/2 ,Stainless steel 316L |
J |
G31/2 ,Stainless steel 316L |
F |
Flange connection (larger than DN50) |
Y |
Special customization |
Output method |
I |
(4~20)mA |
H |
(4 ~20)mA/Hart |
M |
Modbus communication protocol available |
Power supply |
D |
DC24V |
A |
AC220V |
Lightning protection |
I |
Built-in |
E |
External |
N |
None |
Wire system |
T |
Two-wire system |
F |
Four-wire system |
Display |
X |
None |
L |
LCD |
F |
Split gauge outfit display |
Housing material |
A |
Cast aluminum alloy |
S |
Stainless steel |
Housing type |
S |
Single chamber |
D |
Dual chambers |
Electrical interface |
M |
M20 × 1.5 |
G |
G 1/2" |
N |
NPT 1/2" |
Y |
Special customization |