Hollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter

Product Details
Customization: Available
Type: Differential Pressure Transmitter
Structure Type: Mono-Crystalline Silicon
Still deciding? Get samples of US$ 899/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 60 foreign trading staff(s) and 38 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (34)
Find Similar Products

Basic Info.

Model NO.
AT5010 DN50 Single Flange Level Transmitter
Measuring Medium
Fluids Compatible with Contact Material
Accuracy Grade
±0.075%, ±0.05% (Optional)
Pressure range
-500 Kpa to 10 MPa (Minimum Range 0 to 200 PA)
IP Rating
IP67
Certification
Sil2/3, Nace, Nepsi, Atex, CE
Customized
Customized
Flushing Ring
DN50, 316 Stainless Steel, Clamping Type
Extended Warranty
2-Year/3-Year Warranty
Caliber
DN50 and Other Customized Size
Transport Package
Transported in Standard Packaging
Specification
18 cm*18 cm*25 cm
Trademark
HollySys
Origin
China
HS Code
9026201090
Production Capacity
50, 000+ PCS/Year

Product Description

Hollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
Introduction
AT5010 differential pressure level transmitter is a high-performance pressure transmitter with international leading technology carefully developed by using the world's advanced monocrystalline silicon sensor technology and patented packaging process. The monocrystalline silicon sensor is located at the top of the metal body, away from the contact surface of the medium, to achieve mechanical isolation and thermal isolation. The sintered glass integrated sensor leads achieve high-strength electrical insulation with a metal matrix, improving the electronic circuit's flexible performance and ability to withstand transient voltage protection. These monocrystalline silicon sensor packaging technologies ensure that AT5010 differential pressure level transmitter can handle complex chemical and mechanical loads, while providing strong electromagnetic interference resistance for demanding industrial environment applications.

Features
·  SIL2/3, NACE, NEPSI, ATEX, CE
·  -100 kPa to 1 MPa (minimum range 0 to 1 kPa)
·  4 to 20 mA + HART 7, Modbus-RTU/RS485 and others
·  ±0.2% upper limit, ±0.1% upper limit (special tailor-made)
·  Maintainable within 0.1% over a period of 10 years in the URL
·  Static pressure up to 40 MPa
·  Protection level: SIL2/3, Ex ia IIC T4 Ga, Ex db IIC T4...T6 Gb, IP67
·  Intuitive interface and built-in buttons for quick commissioning of the device
·  316L/HC/Tantalum/316L coated with PTFE/316 L gold plated
·  Multiple standard process connections, as well as filler fluids, enabling connection to various forms of piping
·  Combination of more complex level and volume flow measurements possible
·  Convenient and user-friendly, wide options in forms and material
·  Isolation diaphragms with the unique design, featuring anti-overloading
·  Intelligent diagnosis, self-diagnosis, sensor diagnosis, and process variable diagnosis
·  Electrical interface titled down by 10°, which can effectively avoid water inflow caused by improper installation
·  Innovative calibration algorithm, which guarantees accurate measurement of a sensor in a wide temperature range

Applications
Pressure, level, differential pressure, density, interface, flow rate

Product Images
Hollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
Hollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
Technical Specifications
DN50 Single Flange Level Transmitter
Parameter Class Specification Code Clarification
T5010   DN50 single flange level transmitter (±0.2% FS accuracy)
Type LT Monocrystalline silicon sensor (gauge pressure -100 kPa to 1 MPa, minimum range 0 to 1 kPa)
Range 2 0 to 6 kPa (minimum range 0 to 1 kPa)
3 0 to 40 kPa
4 0 to 250 kPa
5 0 to 1 MPa
Sealing method W Stainless steel welded seals
Electrical connection & housing -E1 Aluminum housing, polyurethane coating, female thread 1/2 NPT cable entry
-E2 Aluminum housing, polyurethane coating, female thread M20 * 1.5 cable entry
-E3 SUS316 stainless steel housing, female thread 1/2 NPT cable entry
-E4 SUS316 stainless steel housing, female thread M20 x 1.5 cable entry
Output signal S7 24 V DC loop power supply, 4 to 20 mA, HART 7, two-wire
R Modbus RTU, four-wire, 24 V DC loop power supply,
Display mode M0 Without display
M5 LCD with backlight display module, physical buttons and magnetic bar
Connection type -H The high pressure end is a movable flange mounting connection and the low pressure end is 1/4 NPT female thread.
Isolation fluid S Normal temperature silicone oil, temperature range -40 to 205°C
H High temperature silicone oil, temperature range 0 to 315°C
Flange material S4 Stainless steel SUS304
S6 Stainless steel SUS316
Isolation diaphragms A SUS316L Stainless steel
C Tantalum (316 for process connections)
P SUS316 and PTFE coating (range > 50 kPa)
H Hastelloy C (316 for process connections)
G 316L gold plated
Process connection H20 HG/T 20592-2009 DN50 RF, PN10 to PN40
H21 HG/T 20592-2009 DN50 RF, PN64
H22 HG/T 20592-2009 DN50 RF, PN100
X For other connection specifications, please consult the factory.
Insert tube D0 No Insert tube
D505 OD 46 mm, length 50 mm
D510 OD 46 mm,length 100mm
D515 OD 46 mm, length 150 mm
Process
connectors
C1 Freedom flange, external thread M20 x T5 with lead pipe 914x 2 x 30 mm, SS304
C2 Freedom flange, 1/2-14 NPT female thread, SUS304 stainless steel
NA Unavailable
Anti-explosion d ExdbllCT6, NEPSI
i ExlallCT4, NEPSI
NA Unavailable
Contact medium
treatment
T Degreasing (removing oil and grease from product surface)
NA Unavailable
Extended
warranty
2W 2-year warranty
3W 3-year warranty
Flushing ring R50 DN50, 316 stainless steel , clamping type
Subsidiary requirements EN English stainless steel nameplate and stainless steel anti-explosion cable gland


Special
certifications

 
SIL SIL
Ad ATEX Exd
Ai ATEX Exia
CE Certificate of Compliance
Id IEC Exd
li IEC Exia

Alarm output
 
HH NAMUR NE43 analog output, high alarm, 20.8 mA
LL NAMUR NE43 analog output, low alarm, 3.8 mA
NA Unavailable

Packaging & Delivery
Category Product Size International Commercial Terms (Incoterms) Terms of Payment Nearest Port
AT5010 DN50 Single Falnge Level Transmitter 18 cm*18 cm*25 cm CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou, Tianjin

Related Products
AT5010 Differenrial Pressure Transmitter
Hollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level TransmitterAT5010 Dual Flange Level TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
AT5020 Pressure TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
AT5020 Single Flange Pressure TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
AT4500S Sanitary Pressure TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter
Company Profile
Hollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level TransmitterHollysys 4 to 20mA+Hart 7 Modbus-RTU/RS485 At5010 DN50 Single Flange Level Transmitter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier