Hollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube Rotameter

Product Details
Customization: Available
After-sales Service: as Required
Warranty: as Required
Still deciding? Get samples of US$ 2999/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 60 foreign trading staff(s) and 38 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (34)
Find Similar Products

Basic Info.

Model NO.
AFM2000 Metal Tube Rotameter
Accuracy
1.0, 1.5
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Size
DN15 to DN150
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Output Signal
4 to 20mA Two-Wire Output
Transport Package
Standard Packing
Specification
400mm*200mm*180mm
Trademark
HollySys
Origin
China
HS Code
9032899099
Production Capacity
5000 Sets/Year

Product Description

AFM 2000 series metal tube rotameter is a variable-area flow instrument by locating the rotor. It is made by metal with design of modular. AFM 2000 has characteristics of small volume, small pressure loss, large range ratio, easy installation and maintenance, so it is widely used in complex, harsh environment in various industries to measure and control small flow with low flow rate and all kinds of harsh medium conditions.

The international advanced contactless magnetic sensor is adopted in AFM2000 series metal tube rotameter with single chip microprocessor system. It has functions of liquid crystal display, accumulation, far transmission and upper and lower limit alarm output. With high accuracy and reliability, better performance, multi-parameter calibration, power down protection and other features, the instrument can completely replace the imported instrument of the same type. According to different user's needs and different occasions, there are a variety of measurement forms of AFM2000 series metal tube rotameter for users to choose.

According to the output form, there are local indication type, remote transmission type, control alarm type. According to the classifi cation of explosion-proof requirements, it can be divided into ordinary type, intrinsically safe type, isolation explosion-proof type. According to user's field process flow requirements, there are different way of installation including vertical mounting type (AFM2000-0), upward downward mounting type (AFM2000-1), side in side out mounting type (AFM2000-2), bottom in side out mounting type (AFM2000-3), threaded connection type (AFM2000-4) and horizontal mounting type (AFM2000-6R/L).
Hollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube Rotameter
Features
·  Modular design, easy to maintain, maintenance free for normal use.
·  Simple and practical, low installation cost, and on-site measurement without the need for auxiliary power supply.
·  General concept of explosion-proof: integration of isolation explosion-proof and Intrinsic safety explosion-proof.
·  Flexible measurement methods: flow direction horizontal, bottom-up, bottom-up, left and right, bottom side.
·  All metal structure, earthquake resistant, pressure resistant, temperature resistant, and corrosion resistant.
·  Multiple lining materials: 304, 316, 316L, Hastelloy, PTFE lining, etc.
·  Flexible connection methods: flanges, threads, quick clamps, etc.
·  Measurement amplitude width: 10:1; 20:1 in special circumstances.
·  Various power sources (220V AC, 24V DC, battery powered).
·  Multi variable output (current 4 20mA, can communicate with HART, Modbus 485 communication).

Functions
·  LCD: Support customizing the display of instantaneous value, the accumulated value, current output value and percent of range.
·  Output signal: 4 ~ 20MA two-wire output.
·  HART Communication: Support universal HART protocol; Modbus protocol.
·  Configuration functions: Configurate engineering units, media state, medium density, operating pressure, operating temperature, the density of the rotor, measuring range, variables display, alarm and so on; reset accumulated flow and adjust zero.
·  Protection function: Set limit superior and limit inferior protection values; 3.8mA or 22mA will be the output when it is below the limit inferior or above the limit superior.
·  Monitoring functions: On-line monitoring of instantaneous value, its percentage, output current and accumulated value etc.
·  Calibration function: Calibrate analog output current.
·  Demarcation function: Demarcate 5 to 16 points.
·  Reset master variable: Zero adjustment function.
·  Power-down protection: Data will not be lost in case of power down.
·  LCD backlight: LCD with backlight can make it easier to observe instruments at night or in dark light.
·  Storage of accumulated value: Store accumulated values and change storage cycles.
·  In-place configuration function: Configurate engineering units, media state, medium density, operating pressure, operating temperature, the density of the rotor, measuring range, displayed variables and alarm and protection value. Reset accumulated values, adjust zero and recover data.
·  Current output adjustment: Adjust current of 4mA and 20mA.
·  Data backup and recovery: After the instrument confi guration and calibration, the manufacturer will make factory backup of the original information. If the on-site personnel cannot work normally due to abnormal adjustment of the instrument, the password "5942" can be entered into the data recovery function of data operation, and the manufacturer's factory information can be selected to override the user's illegal error information, so as to reach the normal working state.
·  Achievable parameter setting: Multi-parameter calibration, automatic ambient temperature compensation function.
·  Users revision: Users can amend 5-points on the scene (to adjust curves of the instrument).

Technical parameters
Product Model Technical Parameters AFM2000-0 AFM2000-1/2/3
Instrument diameter DN15~DN150
Measuring range Water (20ºC ) 16~150000L/h;
Air (20ºC 0.1013MPa) 0.5~5000m3/h
Range ratio Standard: 10:1; Particular: 20:1
Accuracy 1.0 level; 1.5 level
Height Standard: 250mm (Please consult the manufacturer about the particular one)
Wetted materials R0 (316) R1 (304) RL (316L) RP (PTFE lining) RC (Hastelloy C) RT (Ti titanium lining) R0 (316); R1 (304); RL (316L);
Pressure level Standard: DN15~DN50 4.0MPa;
DN80~DN150  1.6MPa;
Particular: DN15~DN50  5~42MPa;
DN80~DN150 2.5~16MPa; Jacketed pressure rating: 1.6MPa;
Standard: DN15~DN50 4.0MPa; DN80~DN150 1.6MPa;
Particular: DN15~DN50 5~42MPa; DN80~DN100 2.5~25MPa;
DN150 2. 5~16MPa
Connection Flange Standard: HG/T20592-2009;Or any other standards specified by users
Ambient temperature -40ºC ~120ºC , Flameproof: -20ºC ~+40ºC , Intrinsically Safe: -20ºC ~+40ºC
Medium temperature Standard -40ºC ~+120ºC ; Particular -80ºC ~+350ºC ; PTFE lining ≤ 80ºC
Signal output Two-wire 4~20mA output; Hart communication; Two-wire prefabricated switch sensor, 8V DC power supply;
Power supply Standard: 24VDC (10.8V DC~28V DC) AC type: 220V AC (85~265V AC)
Battery type: 3.6V-9Ah lithium battery
Explosion-proof levels Intrinsically Safe: Exia II CT6 Ga   Flameproof: Exd II CT6 Gb
Protection class IP65

Medium viscosity
DN15: ≤ 5mpa.s (H15.1~15.3)
≤ 30mpa.s (H15.4~15.9) DN25: ≤ 250mpa.s
DN50~DN150: ≤ 300mpa.s
Way of display On-site pointer display; LCD
Electrical connections 1/2"NPT; M20×1.5
Product Model Technical Parameters AFM2000-4 AFM2000-5
Meter diameter DN15~DN100 DN15~DN100

Measuring range
Water (20ºC ) 16~100000L/h Air (20ºC 0.1013MPa) 0.5~3000m3/h Water (20ºC ) 16~100000L/h Air
(20ºC 0.1013MPa) 
0.5~3000m3/h
Range ratio Standard: 10:1; Particular: 20:1
Accuracy 1.0 level; 1.5 level
Height Standard: 250mm (Please consult the manufacturer about the particular one)
Wetted materials R0: 316; R1: 304; RL: 316L; R0 (316); R1 (304); RL (316L);

Pressure level
Standard: DN15~DN50 4.0MPa
please consult the manufacturer about the particular one
Standard: DN15~DN100 1.6MPa
please consult the manufacturer about the particular one
Connection Pipe thread; SMS Thread Jacket (quick connector)
Ambient temperature -40ºC ~120ºC , Flameproof: -20ºC ~+40ºC , Intrinsically Safe: -20ºC ~+40ºC
Medium temperature Standard -40ºC ~+120ºC ; Particular -80ºC ~+350ºC
Signal output Two-wire 4~20mA output; Hart communication;
Two-wire prefabricated switch sensor, 8V DC power supply;
Power supply Standard: 24VDC (10.8VDC~28VDC) AC type: 220VAC (85~265VAC)
Battery type: 3.6V-9Ah lithium battery
Explosion-proof level Intrinsically Safe: Exia II CT6 Ga   Flameproof: Exd  II CT6 Gb
Protection level IP65

Medium viscosity
DN15: ≤ 5mpa.s (H15.1~15.3)
≤ 30mpa.s (H15.4~15.9) DN25: ≤ 250mpa.s
DN50~DN100: ≤ 300mpa.s
Display method On-site pointer display; LCD
Electrical connection 1/2"NPT; M20×1.5;
Product Model Technical Parameters AFM2000-6 R/L
Meter diameter DN15~DN50 DN80~DN150
Measuring range Water (20ºC ) 16~25000L/h Air (20ºC 0.1013MPa)
0.5~1000m3/h
Water (20ºC ) 16~150000L/h Air (20ºC 0.1013MPa)
1000~4000m3/h
Range ratio Standard: 10:1; Particular: 20:1
Accuracy 1.0 level; 1.5 level
Height 250mm 250mm or 350-400mm
Wetted materials R0: 316; R1:304; RL: 316L; R0 (316); R1 (304); RL (316L);
Pressure level Standard: DN15~DN50 4.0MPa
Particular: DN15~DN50 6.3MPa
Standard: DN80~DN150 1.6MPa
Particular: DN80~DN50 6.3MPa
Connection Flange Standard: HG/T20592-2009; Or any other standards specified by users
Ambient temperature -40ºC ~120ºC , Flameproof: -20ºC ~+40ºC , Intrinsically Safe: -20ºC ~+40ºC
Medium temperature Standard -40ºC ~+120ºC ; Particular -80ºC ~+350ºC

Signal output
Two-wire 4 ~ 20mA output; Hart communication; Two-wire prefabricated switch sensor, 8V DC power supply;

Power supply
Standard: 24VDC (10.8VDC~28VDC) AC type: 220VAC (85~265VAC)
Battery type: 3.6V-9Ah lithium battery
Explosion levels Intrinsically Safe: Exia II CT6 Ga   Flameproof: Exd  II CT6 Gb
Protection class IP65

Medium viscosity
DN15: ≤ 5mpa.s (H15.1~15.3)
≤ 30mpa.s (H15.4~15.9) DN25: ≤ 250mpa.s
DN50~DN150: ≤ 300mpa.s
Way of display On-site pointer display; LCD
Electrical connections 1/2"NPT; M20×1.5;

Drawings
Hollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube Rotameter

Packaging & Delivery
Category International Commercial Terms (Incoterms) Terms of Payment Nearest Port
AFM2000 Metal Tube Rotameter CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou, Tianjin

Company Profile
Hollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube RotameterHollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube RotameterHollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube RotameterHollysys Small Volume/Pressure Loss Large Range Ratio Afm2000 Metal Tube Rotameter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier