Basic Info.

Model NO.
Coriolis Mass Flowmeter
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN10-DN250
Application
Industrial Production
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid, Gas
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Density Measuring Accuracy
±1kg/M3
Process Temperature Range
-40ºC to+350ºC
Output Signal
4 to 20 Ma/Hart; Modbus
Display
LCD Display
Explosion-Proof / Protection Grade
Ex Ia LLC T6 Ga/IP67
Frequency
26GHz
Transport Package
as Required
Specification
223mm*140mm*431mm
Trademark
HollySys
Origin
China
HS Code
9026100000
Production Capacity
50, 000+ PCS/Year

Product Description

Hollysys High Accuracy Flow Measurement Mass Flowmeter & Density Meter
Hollysys High Accuracy Flow Measurement Mass Flowmeter & Density Meter

Technical Parameter
P Series Precise Mass Flow & Density Meter
·  Applied to Liquid, Gas, Slurry Mass Flow
·  Mass Flow Accuracy: ±0.1%(Liquid),±0.5%(Gas)
·  Density Measuring Accuracy: ±1kg/m3
·  Normal Diameter: DN10 to DN250
·  Process Temperature Ranges: -40ºC to +350ºC


Z Series Mass Flow & Density Meter
·  Mass Flow Accuracy: ±0.10% / ±0.15% / ±0.20%
·  Density Measuring Accuracy: ±2kg/m3
·  Normal Diameter: DN1~DN40
·  Process Temperature Ranges: -40ºC to +350ºC


Order Information
P Series Precise Mass Flow & Density Meter
OptionsCodesCodes Explanations
Product SeriesPP Series Precise Mass Flow Meter


Sensor Ttype
100 to 1500 kg/h
150 to 4500 kg/h
200 to 9450 kg/h
250 to 25500 kg/h
500 to 94500 kg/h
800 to 240000 kg/h
1000 to 540000 kg/h
1500 to 825000 kg/h
2000 to 1650000 kg/h
2500 to 2700000 kg/h
Transmitter TypeW000None
D100DPT100 (Accuracy 0.1, Chinese interface, IP65, Exde ibllCT6, Divided installation)
D101DPT100 (Accuracy 0.1, Chinese interface, IP65, Exde ibllCT6, Divided installation)
D102DPT100 (Accuracy 0.1, Chinese interface, IP65, Exde ibllCT6, Divided installation)
D103DPT100 (Accuracy 0.1, Chinese interface, IP65, Exde ibllCT6, Divided installation)
D104DPT100 (Accuracy 0.1, Chinese interface, IP65, Exde ibllCT6, Divided installation)
D105DPT100 (Accuracy 0.1, Chinese interface, IP65, Exde ibllCT6, Divided installation)
Sensor CharacteristicsB316L & 304, Temperature-ristance 250ºC
C316L, Temperature-ristance 350ºC
R316L & 304, Steam heat tracing
D316L & 304, Electric heat tracing
L316L
HHastelloy C22
TSpecial orders
Power supply mode0None
118VDC to 36VDC
218VDC to 36VDC
3Smart power
4Sensor 220VAC, Transmitter 24VDC
Process ConnectionAGB/T9115.1-2000, RF welding neck flange, 4MPa, RF
CGB/T9115.1-2000, RF welding neck flange, 6.3MPa, RF
EHG/T20615.1-2009, RF welding neck flange, Class300, WN-RF
FASME B16.5-1988, RF welding neck flange, Class150, WN-RF
GASME B16.5-1988, RF welding neck flange, Class300, WN-RF
IGB/T20592-2009, RF welding neck flange, 4MPa, RF
TSpecial orders
Process Connection DiemisionsBDN15
DDN25
FDN40
Power Supply GDN50
HDN65
IDN80
JDN100
Connection ProcessLDN150
MDN200
NDN250
ODN300
TSpecial orders
Accessory0None
110m Cable
2Carbon steel flange, Bolt and nut, Metal gasket, 10m cable
3Stainless steel flange, Bolt and nut, Metal gasket, 10m cable
4Carbon steel flange, Bolt and nut, Metal gasket
5Carbon steel flange, Bolt and nut, Metal gasket
9Special orders
Transmitter Power and Signal Line Electrical InterfaceWNone
MM20
N1/2NPT
P3/4NPT
GG1/2
EG3/4
TSpecial orders
Communication and Data Collection Methods0None
1Active circulation (4-20mA), Active frenquency (0-10KHz), RS-485
2Active circulation (4-20mA), RS-485
3Active frenquency (0-10KHz), RS-485
4Passive frenquency (0-10KHz), RS-485
5Active circulation (4-20mA), Active frenquency (0-10KHz), Passive HART
6Active circulation (4-20mA), Active frenquency (0-10KHz), Active HART
7Passive frenquency (0-10KHz), Active HART
9Special orders
Measurement ModeGTrade transaction type
BStandard measurement type
DGas measuring type 9accuracy 0.35)
ZUndefined

Z Series Mass Flow & Density Meter
OptionsCodesCodes Explanations
Product SeriesZZ Series Mass Flow Meter


Sensor Models
1(0~41)kg/h
2(0~110)kg/h
3(0~350)kg/h
6(0~1500)kg/h
15(0~3000)kg/h
20(0~10800)kg/h
25(0~25500)kg/h
40(0~40500)kg/h
Sensor Type NStandard
VMicrobending
Transmitter TypeIAll-In-One (Standard) +OLED Display
HAll-In-One (Enhanced)+Image Display+Protection Output
RSplitting type (Standard)+OLED Display
FSplitting type (Enhanced)+Image Display+Protection Output
Accuracy 2Liquid 0.15%
3Liquid 0.1%
7Gas 0.35%
Verification Certificate0Factory(Liquid)Verification Certificate
1Factory(Liquid)Calibration Certificate
2(Gas)Verification Certificate
3Density calibration
5Verification Certificate of National Calibration Institution for Density Calibration
Software 0Standard Configuration
1Gas measurement type
3Density measurement type
7Two phase flow measurement type
Sensor MaterialL316L
F304L
HHC-22
Sensor Type1304 Standard
2304 Standard+Heat tracing jacket
3304 Standard+Burst disc
4316L Standard
5304 Standard+Salt spray prevention treatment
Temperature A-40~125ºC
C-40~200ºC
Cleanig BStandard
PHygienic treatment
WDegreasing treatment
Power Supply 124VDC
2220VAC
3220VAC & 24VDC
5220VAC&24VDC + Degreasing treatment surge protection
Connection ProcessBGB/T9115    PN16      WN
HGB/T9115    PN25       WN
AGB/T9115    PN40       WN
CGB/T9115    PN63      WN
YGB/T9115    PN160     WN
FASME B16.5   Class150 WN
GASME B16.5   Class300 WN
KASME B16.5   Class600 WN
VASME B16.5   Class900 WN
Connection ProcessSASME B16.5   Class1500 WN
NHG/T 20592  PN16       WN
MHG/T 20592  PN25       WN
IHG/T 20592  PN40       WN
LHG/T 20592  PN63       WN
XHG/T 20592  PN160      WN
JHG/T 20615  Class150   WN
EHG/T 20615  Class300   WN
PHG/T 20615  Class600  WN
WHG/T20615   Class900  WN
UHG/T20615   Class1500 WN
TSpecial Requirements
Tongjing BDN15
DDN25
FDN40

Sealing
1RF
2Raised face M(Female FM)
3Convex T(Groove surface G)
6RJ
9Special Requirements
Cable AArmored cable
SStandard cable(5m)
ZNone
Annex 0None
2Carbon steel flanges, bolts and nuts, metal winding gaskets
3Stainless steel flanges, bolts and nuts, metal winding gaskets
4HC22 flanges,bolts and nuts, metal winding gaskets
Electrical InterfaceMElectrical interface without device 2×M20
NElectrical interface without device 2×1/2NPT
PElectrical interface without device 2×3/4NPT
GElectrical interface without device 2×G1/2
EElectrical interface without device 2×G3/4


Output
1Active 4~20mA,Active 0~10KHz,Mudbus
22 × Active 4~20mA,Mudbus
32 × Active 0~10KHz,Mudbus
4Passive 4~20mA,Passive 0~10KHz,Mudbus,HART
5Active 4~20mA,Active 0~10KHz,HART
7Passive 4~20mA,Passive 0~10KHz,FF
9Special Requirements
Authent
ication
MMaterial certification
SSIL certification
JQuality Assurance Certificate
VClassification certificate
ZNone
Additional FunctionAPressure Compensation
BSelf diagnosis
CSelf calibration
RData Record
ZNone

Company ProfileHollysys High Accuracy Flow Measurement Mass Flowmeter & Density MeterHollysys High Accuracy Flow Measurement Mass Flowmeter & Density MeterHollysys High Accuracy Flow Measurement Mass Flowmeter & Density MeterHollysys High Accuracy Flow Measurement Mass Flowmeter & Density Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.