Signal: 4~20mA; 0~20mA; Binary; Soe
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: CE, Eac; TUV; Sil2; G3
Condition: New
Customized: Customized
Housing: Plastic Sealing Process
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 60 foreign trading staff(s) and 38 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (34)

Basic Info.

Model NO.
LKS Safety PLC
Signal Type
4-20 Ma Hart
Control Type
Process Control
Transport Package
Transported in Standard Packaging
Trademark
HollySys
Origin
China
HS Code
8537101101
Production Capacity
8, 000 Sets/Year

Product Description

Hollysys High Performance & Reliability Functional Safety Sil2 Programmable Logic Controller Lks PLC
Introduction
LKS functional safety PLCs are the first set of dual-rack redundant safety PLCs developed by HollySys. They passed the SIL2 certification of TÜV SUD and comply with IEC61508, IEC61511 and EN50128, EN50129, EN50126 and IEC61784-3 standards. They adopt the latest electronic technology and single-loop diagnostic architecture (1oo1D) design. LKS functional safety PLCs can be applied to safety-related systems requiring a safety integrity level of SIL2 or below, such as Emergency Shutdown (ESD) system, Process Shutdown (PSD) system, and Burner Management System (BMS), Fire & Gas System (FGS), Emergency Trip System (ETS), and Gas Detection System (GDS) to provide safe and reliable solutions for different fields.
 
Features

·  System with 1001D architecture and SIL2 certification
·  Dual-rack redundancy configuration, and support for power, CPU, and communication redundancy
·  Dual-core CPU with asymmetric AMP heterogeneous technology
·  Controller adopting the safety and security fusion technology
·  Over 90% of diagnosis coverage and over 100,000 h of MTBF
·  International safety standards and safety protocols compliant in process and rail industry
·  Operating temperature ranging from -40ºC to +70ºC and storage temperature ranging from -40ºC to +80ºC
·  TÜV Rheinland certified reliability test center
·  Implementation of hundreds of functional safety projects
·  Participation in the preparation of national functional safety standards
·  TÜV Functional Safety Engineer

Technical Specifications
Safty CPU Module LK220S
Operation Speed
CPU dominant frequency Dual-core, 667 MHz
Instruction execution speed Typical value: 2.5 DMIPS/MHz
Memory
Program storage 32 MB (16 MB for the system and 16 MB for users)
Memory 512 MB, 800 Mbit/s, 32-bit width
Power-off hold 512 KB
Expanding storage SD card, up to 32 GB
Ethernet
10/100M Two-channel, dual-network-port redundancy, Modbus TCP protocol supported
Real Time Clock
Data format Year:month:day:hour: minute:second, BCD code
Clock accuracy Not more than 1 minute/month @25° C
Backplane Bus
Communication Speed 2.5 Gb/S
Load Capacity 1×4 route
Hot Swap
Module hot swap Support
System Capacity
I/O capacity The I/O capacity supported by the system is greater than 900 points
Configuration Capacity
Input variable area (I) Maximum space: 128 KB
Input variable area (Q) Maximum space: 128 KB
Global variable area (G) Maximum space: 1 MB
Free variable zone (M) Maximum space: 1 MB
Power-off holding area (R) Maximum space: 64 KB
Special register area (S) 16 KB
Power
Power supply Provided by backplane
Module (max.) 300mA @24VDC
Backup battery Capacitor power supply
Redundancy
Dual backplane redundancy Support hot-standby
Start Time
Duration from module power-on to
user project start
≤ 60s
Physical Characteristics
Installation mode Backplane Slot
Module dimensions (W×H×D) 44.7 mm ×166 mm ×152 mm
Weight 382 g
Environmental Conditions
Operating temperature 0ºC to +60ºC
Storage temperature -40ºC to +70ºC
Relative humidity 5% to 95% non-condensing

Packaging & Delivery
Category International Commercial Terms (Incoterms) Terms of Payment Nearest Port
LKS Functional Safty PLC CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou, Tianjin

Company Profile
Hollysys High Performance & Reliability Functional Safety Sil2 Programmable Logic Controller Lks PLCHollysys High Performance & Reliability Functional Safety Sil2 Programmable Logic Controller Lks PLCHollysys High Performance & Reliability Functional Safety Sil2 Programmable Logic Controller Lks PLCHollysys High Performance & Reliability Functional Safety Sil2 Programmable Logic Controller Lks PLC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Registered Capital
17.74 Million USD
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment