Customization: | Available |
---|---|
Signal: | 4-20mA; 0-20mA; 0-10V; Tc; Rtd; Mv; Binary; Pulse |
Function: | Automatic Control, Protection, Monitoring, Measurement |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Environmental conditions | Transportation and storage |
Temperature | Standard: IEC 60068-2-1 | -40ºC to +70ºC |
Humidity | IEC 60068-2-2 | 5% to 95%, non-condensing | ||
Dumping and overturning | Standard: IEC 60068-2-30 | 50 mm falls 4 times, unpacked | ||
Free fall | Standard: IEC 60068-2-31 | 1 m 5 times, transport and packaging | ||
Working conditions |
Temperature | Standard: IEC 60068-2-1 IEC 60068-2-2 |
0 to +60ºC |
|
Temperature variation | Standard: 1 EC 60068-2-14 |
5 to 55ºC 3°C/min | ||
Mechanical vibration | Standard: IEC 60068-2-27 |
15 G, 11 ms pulse, 6 times per axial direction | ||
Sine wave vibration | Standard: 1 EC 60068-2-6 |
Peak-peak 0.3 mm, frequency 10 to 57 Hz, 2 G/panel installation, guide rail installation, 57 to 150 Hz, 10 vibrations per axis, 1 frequency range/minute |
||
Mechanical protection rating | Standard: EN 60529 |
IP20 | ||
Electro-magnetic compatibility | All interfaces | Electrostatic discharge | Standard: IEC61000-4-2 |
1. Contact discharge: 4 kV;
2. Air discharge: 8 kV
|
Power frequency magnetic field immunity | Standard: IEC61000-4-8 |
Steady continuous magnetic field test Magnetic field strength 30 A/m |
||
Radio frequency electromagnetic field |
Standard: IEC61000-4-3 |
80 MHz to 1 GHz 10 V/m, 80% modulated with 1 KHz signal |
||
RF field induced conductive disturbance | Standard: IEC61000-4-6 |
0.15 to 80 MHz, 3 V RMS | ||
AC power supply | Voltage dips and interruptions immunity test | Standard: IEC61000-4-11 |
0.5 cycles of each polarity interruption | |
Fast transient burst immunity test | Standard: IEC61000-4-4 |
2 kV | ||
Surge immunity | Standard: IEC61000-4-5 |
Line-to-line 1 kV, line-to-GND 2 kV |
||
Communications | Surge immunity | Standard: IEC61000-4-5 |
Line to ground 1 kV | |
I/O | Fast transient burst immunity test | Standard: IEC61000-4-4 |
1 kV | |
Test of radiated interference | Standard: IEC 61131-2 |
1. 30 to 230 MHz 10 m quasi-peak value less than 40 dB (μV)
2. 230 to 1000 MHz 10 m quasi-peak value less than 47 dB (μV)
|
||
Electro-magnetic Radiation | Test of conducted interference | Standard: IEC 61131-2 |
1. 0.15 to 0.5 MHz quasi-peak value less than 79 dB (μV) and average value less than 66 dB (μV)
2. The quasi-peak value of 0.5-30 MHz is less than 73 dB (μV), and the average value is less than 60 dB (μV)
|
Category | International Commercial Terms (Incoterms) | Terms of Payment | Nearest Port |
LE Compact PLC | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |