LX-CU500 Controller |
Item |
Specifications |
Power supply |
Field power |
Voltage range |
24 V DC (19.2 V to 30 V) |
Anti-reverse connection |
Support |
Redundancy input |
Support |
System power |
Voltage range |
24 V DC (19.2 V to 30 V) |
Anti-reverse connection |
Support |
Storage |
Input variable area (I) |
256 KB |
Output variable area (Q) |
256 KB |
Global variable area (G) |
6 MB |
Global variable area (M) |
8 MB |
Power-loss retentive area (R) |
500 KB |
Program storage (Users) |
6 MB |
SD expansion card |
Expandable with a micro SD card, up to 32 GB |
Program scanning and multi-tasking |
Multi-tasking |
Supporting both single-task and multi-task configurations |
Number of tasks |
16 |
Task type |
Supporting periodic, loop, state, event, and one-time task |
Periodic task scope |
1 ms to 2,000 ms, default is 20 ms |
Motion control |
Servo task cycle |
500 μs of the minimum task cycle |
Motion control instruction |
Multi-axis control, electronic gear, electronic cam, absolute positioning, relative positioning, synchronization, speed control, origin, jog interpolation |
The maximum axis |
64-axis servo or inverter |
Motion control method |
Supporting EtherCAT motion control and pulse contro |
Ethernet bus 1 (P0/P1 northbound network) |
Communication ports |
2 ports (P1, P2) |
Voltage level standard |
IEEE 802.3 |
Communication rate (bps) |
1,000 Mbps |
Communication protocol 1: ModbusTCP master/slave station protocol |
Polling time: 10 ms |
Connections: 32 |
Communication protocol 2: TCP/IP free protocol |
Data input and output areas size: 1 to 32 K |
Connections: 16 |
Communication protocol 3: EtherNet/IP protocol |
Data input and output areas size: 502 B ×15 |
Connections: 15 (read while write) |
Communication protocol 4: hlink protocol |
Data input and output areas size: 1 KB |
Connections: 10 |
Serial communication |
Interface quantity |
1 |
Interface type |
Pluggable |
Voltage level standard |
RS-485 |
Protocol type |
ModbusRTU master/slave, free ports |
Transmission mode and frame format |
RTU |
Supported function codes |
01, 02, 03, 04, 05, 06, 0F, 10 (in hexadecimal) |
Maximum number of supported slave stations |
Connecting 32 Modbus slave stations |
Cable impedance |
120 Ω |
Communication rate |
Supporting 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 115200 bps, configurable |
Parity check |
Odd, even, or no parity bit (configurable) |
Trigger mode |
Supporting trigger mode to write a function |
Diagnostics function |
Supporting diagnostic reporting (including diagnostics of the status of each slave station) |
Isolation |
Isolation between the field and the system |
Real-time clock |
Data format |
Year: month: day: hour: minute: second, BCD code |
Clock accuracy |
≤ ±60 s/month, supporting time synchronization |
Power-loss rententive time |
1 year (needs to be equipped with an RTC battery) |
Others |
Power-loss retentive |
Support |
Time synchronization |
Supporting NTP time synchronization |
Log function |
Minimum of 10,000 logs |
Module protection level |
IP20 |
Time from module startup to user program initiation |
≤ 30s |
Environmental conditions |
Operating environment temperature |
-20ºC to 60ºC |
Operating environment relative humidity |
5% to 95% non-condensing |
Storage environment temperature |
-40ºC to 70ºC |
Storage environment relative humidity |
5% to 95% non-condensing |